SR982P Solar Working Station
Introduction:
  APPLICATIONS CAPACITY  
  Max.number of collector loops:2  
  Max.number of storage tank loops:2  
  Max.number of relays:4  
  Max.number of sensors:7  
  Max.number of application system:15 
 
Main technical data:
TECHNICAL  DATA 
Dimension:  420mm*280mm*155mm 
Power  supply:200V-240V  AC  or  100V-130V  AC50-60Hz.  .      
Power  consumption:  < 3W 
Accuracy of temperature measuring: ? 2oC 
Range of collector temperature measuring: -10oC ~200oC 
Range of tank temperature measuring: 0oC ~100oC 
Suitable power of pump: 3 pumps possible to be connected power of each pump < 200W . 
Suitable power electrical heating:1 relay for 1500W(1500w-4000w must be use SR802) 
Inputs: 5sensors 
7pcs*Pt1000 sensor (?500oC) for collector (silicon cable?280oC) 
4pcs*NTC10K B3950 sensor (? 135oC) for tank (PVC cable ?105oC) 
Outputs:4 relays for circulation pumps or 3-way electromagnetic valve 
Ambient temperature:-10oC ~ 50oC. 
Water proof grade: IP42. 
Main functions:
MAIN  FUNCTIONS 
 
 
Pump  support: 
1.Normal  Pump. 
2.High  Efficiency  pump. 
 
 
Set  up  clock/week 
 
Functions  operation  and  parameters  setup  (user  grade) 
1  THET  Timing  heating 37 
2  CIRC  DHW  circuilation  function  activated  /deactivated 
3  tCYC  Tempeature  or  time  setting  for  DHW  pump  in  three  time  sections 
 
Functions  operation  and  parameter  setup  (engineer  grade) 
1.  DT  Temperature  difference  for  solar  circuit  pump 
2.  EMOF  Maximum  switch-off  temperature  of  collector  (for  collector  emergency  close  function) 
3.  CMX  Maximum  limited  temperature  of  collector  (collector  cooling  function) 
4.  CMN  Low  temperature  protection  of  collector 
5.  CFR  frost  protection  temperature  of  collector 
6.  REC  Recooling  temperature  of  tank 
7.  SMX1  Maximum  temperature  of  tank  1 
8.  SMX2  Maximum  temperature  of  tank  1 
9.  MAX1  Maximum  switch-off  temperature  for  heat  transfer  between  tank  and  heat  return 
10.  MIN1  Minmium  switch-on  temperature  for  heat  transfer  between  tank  and  heat  return 
11.  MAX2  Maximum  switch-off  temperature    for  heat  transfer  between  heat  exchanger  and  tank 
12.  MIN2  Minmium  switch-on  temperature    for  heat  transfer  between  heat  exchanger  and  tank 
13.  C?F  Switch  between  Celsius  and  Fahrenheit 
 
 
FUN  Auxiliary  functions 
1.  DVWG  Anti  legionnaires'  function 
2  SFB  Switch-on/off  of  the  solid  fuel  boiler 
3.  SFON  Minimum  switch-on  temperature  of  tank 
4.  SFOF  Maximum  switch-off  temperature  of  tank 
5.  MAX3  Maximum  switch-off  temperature  of  solid  fuel  boiler 
6.  MIN3  Minimum  switch-on  temperature  of  solid  fuel  boiler 
7.  PUMP1  P1  pump  operation  mode  selection 
8.  PUMP2  P2  pump  operation  mode  selection 
9.  OHQM  Thermal  energy  measuring 
10.  FTYPE  Flow  meter  type  selection 
11.  FMAX  Flow  rate 
12.  MEDT  Type  of  heat  transfer  liquid 
13.  MED%  Concentration  of  heat  transfer  liquid 
14  Tank  priority 
15.  pump  Intermission  function 
16.COOL  Tank  cooling  function 
17.AHO  Automatical  thermostat  function 
18.BYPR  Bypass  function  (high  temperature) 
19.HND  Manual  control 
20.PASS  Password  set 
21.REST  Recovery  to  factory  set 
22."ON/OFF"Controller  switch  on/off  button 
23.Holiday  function 
24.Manual  heating 
25.Temperature  checking  function 
26.Protection  function 
27.Memory  protection 
28.Screen  protection 
29.Pump  P1/P2  dry  running  protection 
30.Trouble  shooting 
31.Trouble  protection 
32.Trouble  checking  |